Jump to content

Troubleshooting Guide EVC2: Difference between revisions

From Teltonika Energy Wiki
Created page with " __TOC__ <h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">Introduction</h2> <ul style="list-style-type: none; margin: 0; padding: 0;"> Here you can find information about Troubleshooting of our device. <br> <h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">What is the first thing to do when issue comes?</h2> <ul style="list-style-type: none; margin: 0; padding: 0;"> Usually, most of the issues g..."
 
No edit summary
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
__TOC__
<div style="font-family:'Inter','Helvetica Neue',Arial,sans-serif; line-height:1.6;">
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">Introduction</h2>
__TOC__
  <ul style="list-style-type: none; margin: 0; padding: 0;">
 
Here you can find information about Troubleshooting of our device.  
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Introduction</span> ==
<br>
 
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">What is the first thing to do when issue comes?</h2>
This page provides troubleshooting information for EVC 2.
  <ul style="list-style-type: none; margin: 0; padding: 0;">
 
Usually, most of the issues gets solved by going through these simple steps below: <br>
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">What to do first when an issue occurs</span> ==
1. Go to [https://play.google.com/store/apps/details?id=com.teltonika.ems.ev&hl=lt&gl=US Google play] or [https://apps.apple.com/lt/app/teltonika-energy/id1618750750 APP store] to update your '''mobile application version''' to the latest version. <br>
 
2. Go to you charger settings and update charger '''Firmware version''' to the latest. [https://wiki.teltonika-energy.com/view/EVC2_firmware FW update guide] <br>
Most issues can be solved with the following steps:
3. Go to your charger settings and reboot device.
# Update the mobile app to the latest version via [https://play.google.com/store/apps/details?id=com.teltonika.ems.ev&hl=lt&gl=US Google Play] or the [https://apps.apple.com/lt/app/teltonika-energy/id1618750750 App Store].
<br>
# In your charger settings, update the charger firmware to the latest version (see the [https://wiki.teltonika-energy.com/view/EVC2_firmware firmware update guide]).
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">How to check your charger firmware version?</h2>
# Reboot the device from the charger settings.
  <ul style="list-style-type: none; margin: 0; padding: 0;">
 
Simple steps to finding a place in your mobile application where you can check your current TeltoCharge firmware version and update it to the latest. Please always check if you have latest firmware version in your charger.
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">How to check the charger firmware version</span> ==
<br>1. Go to Teltonika Energy app settings and press '''Device info'''; <br>2. Press '''Check for updates'''; <br>3. At the top, current firmware version can be found. <br>
 
Follow these steps to check your current EVC 2 firmware version in the app and update it. Always make sure your charger has the latest firmware.
# Go to the app settings and press '''Device info'''.
# Press '''Check for updates'''.
# The current firmware version is shown at the top.


[[File:FW version check.png|center|frameless|700x700px]]
[[File:FW version check.png|center|frameless|700x700px]]
   
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">How to download troubleshoot file?</h2>
  <ul style="list-style-type: none; margin: 0; padding: 0;">
Simple steps of finding place in your mobile application where you can download '''troubleshoot file'''.
<br>
1. Go to the '''Diagnostics.'''<br>
2. Slide to the bottom. <br>
3. Click '''Troubleshoot file'''. <br>
4  Click '''Download troubleshoot file'''. <br>
5. Wait until '''file downloaded''' message pop-up.<br>
6. Select the downloaded file.<br>
7. '''Click''' At the top right corner and press '''share'''<br>
<br>
'''Note:''' For best results, please download the file '''during charging session.''' Then more details about current situation would be saved.
<br>
[[File:Download guide.png|900x900px|center]]


  <h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">LED indicators</h2>
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">How to download the troubleshoot file</span> ==
  <ul style="list-style-type: none; margin: 0; padding: 0;">
 
===STATUS INDICATIONS===
'''Follow these steps to download the troubleshoot file in the app.'''
{| class="wikitable"
# Go to '''Diagnostics'''.
|+
# Scroll to the bottom.
!A
# Tap '''Troubleshoot file'''.
!B
# Tap '''Download troubleshoot file'''.
!C
# Wait for the ‘file downloaded’ message.
!D
# Select the downloaded file.
!E
# Tap the icon in the top right corner and press '''Share'''.
!F
!G
!H


|-
'''Note:''' For best results, download the file during a charging session, so that more details about the current situation are saved.
|[[File:TeltoCharge LEDS booting up.gif|center|frameless]]
|[[File:White rolldown.gif|center|frameless|alt=|213x213px]]
|[[File:TeltoCharge LEDS Standby White.gif|center|frameless]]
|[[File:TeltoCharge LEDS Standby Yellow.gif|center|frameless]]
|[[File:TeltoCharge LEDS SimplifiedCharging.png|center|frameless]]
|[[File:TeltoCharge LEDS WaitingforEV.gif|center|frameless]]
|[[File:TeltoCharge LED WaitingforAuthorization.gif|center|frameless]]
|[[File:TeltoCharge LEDS OnHold.gif|center|frameless|alt=|202x202px]]


|-
[[File:Download guide.png|900x900px|center]]
|White LED‘s rolling from the bottom to the top – shows that TeltoCharge is booting up
|White LED‘s rolling from the top to the bottom – shows that TeltoCharge is Reserved (OCPP only)
| White pulsing LED‘s – shows that TeltoCharge is in standby mode and waiting for action
|Yellow pulsing LED‘s – shows that TeltoCharge is in standby mode with default settings.
|Yellow LED‘s on – TeltoCharge is not charging, simplified charging sequence is required.
|Blue LED‘s lights up from the middle – TeltoCharge do not require permission, it is waiting for EV to initiate charging process (go to state C).
|Blue LED‘s pulsing – permission to charge is not granted. TeltoCharge requires authorization.
|Blue LED‘s rolldown from up to down
1. Wait for scheduled time.<br>
2. No dynamic power – DLB/DLM/Solar enabled and no sufficient power.<br>
3. EVSE suspended.<br>
4. Reserved charge (OCPP only).


|-
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">LED indicators</span> ==
|
|
|
|Open installer menu via Teltonika Energy app, set and save settings.
|Open installer menu via Teltonika Energy app and select to allow simplified charging sequence
|
|Authorize yourself with app or NFC card.
|1. Go to settings via Teltonika energy APP and select schedule time section to check for set graphs<br>
2. Wait for more available power or increase amperage limits via settings (if your grid allows it)<br>
3. Available power is less than 6 Amperes. Provide more power or wait for more to generate.<br>
4. Other user has already reserved this charging station or RemoteStartTransaction command was received (OCPP only)


|}
=== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Status indications</span> ===


{| class="wikitable"
{| class="wikitable" style="width:100%; text-align:center; table-layout:fixed;"
|+
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | A
!I
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | B
!J
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | C
!K
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | D
!L
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | E
!M
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | F
!N
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | G
!O
|-
|-
|[[File:TeltoCharge LEDS AddNFC.gif|center|frameless]]
| [[File:TeltoCharge LEDS booting up.gif|center|frameless|205x205px]]
|[[File:TeltoCharge LEDS InitialisationOfCharging.gif|center|frameless]]
| [[File:White rolldown.gif|center|frameless|205x205px]]
|[[File:TeltoCharge LEDS Charging.gif|center|frameless]]
| [[File:TeltoCharge LEDS Standby White.gif|center|frameless|205x205px]]
|[[File:TeltoCharge LED ChargingFinished.png|center|frameless]]
| [[File:TeltoCharge LEDS SimplifiedCharging.png|center|frameless|205x205px]]
|[[File:TeltoCharge LEDS RequireVentilation.png|center|frameless]]
| [[File:TeltoCharge LEDS WaitingforEV.gif|center|frameless|205x205px]]
|[[File:TeltoCharge LEDS AuthorizationDeclined.png|center|frameless|alt=|204x204px]]
| [[File:TeltoCharge LED WaitingforAuthorization.gif|center|frameless|205x205px]]
|[[File:TeltoCharge LEDS AuthorizationAccepted.PNG|center|frameless|alt=|204x204px]]
| [[File:TeltoCharge LEDS OnHold.gif|center|frameless|alt=|205x205px]]
|-
|-
|Four middle blue LED’s pulsing – TeltoCharge waiting to add new NFC card
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | H
|Green LED‘s pulsing - Initialisation of charging.
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | I
|Green LED‘s rolling upwards from the bottom – TeltoCharge is in charging process.
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | J
|Green LED‘s on – TeltoCharge finished charging.
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | K
|Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D).
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | L
|Red four middle LED's - NFC/RFID card declined from the server.
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | M
| Green four middle LED's - NFC/RFID card accepted from the server.
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | N
|-
|-
|
| [[File:TeltoCharge LEDS AddNFC.gif|center|frameless|205x205px]]
|
| [[File:TeltoCharge LEDS InitialisationOfCharging.gif|center|frameless|205x205px]]
|
| [[File:TeltoCharge LEDS Charging.gif|center|frameless|205x205px]]
|
| [[File:TeltoCharge LED ChargingFinished.png|center|frameless|205x205px]]
|Open installer menu via Teltonika Energy app and select that charging location is ventilated. To select that charger must be installed in ventilated location.
| [[File:TeltoCharge LEDS RequireVentilation.png|center|frameless|205x205px]]
|Check if NFC/RFID card is in a server cards whitelist.
| [[File:TeltoCharge LEDS AuthorizationDeclined.png|center|frameless|alt=|205x205px]]
|
| [[File:TeltoCharge LEDS AuthorizationAccepted.PNG|center|frameless|alt=|205x205px]]
|}
|}


 
{| class="wikitable" style="width:100%;"
===RED LED INDICATIONS (errors)===
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px; width:5%;" | Ref
{| class="wikitable"
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Description
|+
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Meaning
!A
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Troubleshooting
!B
|-
!C
| style="text-align:center;" | '''A'''
!D
| White LEDs rolling from the bottom to the top
!E
| EVC 2 is booting up.
!F
| Normal behaviour – no action needed.
!G
|-
!H
| style="text-align:center;" | '''B'''
| White LEDs rolling from the top to the bottom
| EVC 2 is Reserved (OCPP only).
| Normal behaviour – no action needed.
|-
|-
|[[File:TeltoCharge LEDS InputVoltageError.png|center|frameless]]
| style="text-align:center;" | '''C'''
|[[File:TeltoCharge LEDS OutputVoltageCurrentError.png|center|frameless]]
| White pulsing LEDs
|[[File:TeltoCharge LEDS CurrentLeakageDetected.png|center|frameless]]
| EVC 2 is in standby mode and waiting for action.
|[[File:TeltoCharge LEDS ConnectivityError.png|center|frameless]]
| Normal behaviour – no action needed.
|[[File:TeltoCharge LEDS TemperatureError.png|center|frameless]]
|[[File:TeltoCharge LEDS OtherErrors.png|center|frameless]]
|[[File:TeltoCharge LEDS FaultyConnection.gif|center|frameless]]
|[[File:Orange_LED_warning_LED.png|center|frameless|alt=|202x202px]]
|-
|-
|Input voltage error.
| style="text-align:center;" | '''D'''
|Output voltage/current error.
| Yellow LEDs on
|Current leakage detected.
| EVC 2 is not charging, simplified charging sequence is required.
|Connectivity error.
| Open installer menu via the app and select to allow simplified charging sequence.
|Temperature error.
|Internal errors.
|Faulty connection to EV.
|Warning orange LED
|-
|-
|Overvoltage;
| style="text-align:center;" | '''E'''
Undervoltage;
| Blue LEDs lights up from the middle
 
| EVC 2 do not require permission, it is waiting for EV to initiate charging process (go to state C).
Wrong wiring.
| Normal behaviour – no action needed.
|Overvoltage;
Undervoltage;
 
Output current.
|Current leakage detected
|Cable lock;
PP fail;
 
Car diode.
|Temperature reached 85°C
| -12V;
|CP fail
|
Problems with energy meter:
*Unrecognized;
*Badly set;
*Communication problems;
Other problems:
*Temperature;
*Current ;
*D state.
|-
|-
| colspan="8" |<center><big>Troubleshooting</big></center>
| style="text-align:center;" | '''F'''
| Blue LEDs pulsing
| Permission to charge is not granted. EVC 2 requires authorisation.
| Authorise yourself with app or NFC card.
|-
|-
| style="text-align:center;" | '''G'''
| Blue LEDs rolldown from up to down
|
|
*Check if input wiring is connected correctly;
# Wait for scheduled time.
*Measure input voltage;
# No dynamic power – DLB/DLM/Solar enabled and no sufficient power.
*Check installer menu settings if supply voltage and voltage tolerance is in accordance with the measured input voltage.
# EVSE (charger) suspended.
# Reserved charge (OCPP only).
|
|
*Disconnect charging cable from the EV and check if the issue remains.
# Go to settings via the app and select schedule time section to check for set graphs
*Reboot charger and try to connect EV again.
# Wait for more available power or increase amperage limits via settings (if your grid allows it)
|
# Available power is less than 6 A. Provide more power or wait for more to generate.
* Disconnect the cable from the EV and check if the error persists.
# Other user has already reserved this charging station or RemoteStartTransaction command was received (OCPP only)
*If the error is cleared, try to start charging. If the error occurs once again, try following steps:
|-
*Check if charging cable is fully pluged into socket and/or EV;
| style="text-align:center;" | '''H'''
*Check if the inside of both the socket and the plug has no foreign materials inside (is clean).
| Four middle blue LEDs pulsing
* Check visually if the cable is not damaged.
| EVC 2 waiting to add new NFC card.
*Check if the boards are not covered in dust and/or other materials.
| Normal behaviour – no action needed.
|
*Check if the charging cable is connected correctly from the charger side (socket version) and from the EV side;
*Try to reconnect charging cable to the EV and EVSE (if it is socket version).
*Listen if you can hear a clicking sound from the TeltoCharge when you plug the cable to EV. Charger should lock cable plug. If you can’t hear, try to unplug cable (from EVSE side) while it is plugged from EV side. If it is possible to unplug, report this problem via VIP helpdesk or your sales manager.
*If any of these steps helps, measure the voltage between PE and PP and check if it is in accordance to the standard.
|
*Check the temperature inside Teltonika Energy app > Device info. If temperature is higher than 85 ℃ wait while charger cools down.
|  
*Restart TeltoCharge
|  
*Try reconnect charging cable from the EV side. There might be control pilot communication problem which can occur with different EV models.
|Go to the live data section and see what is the main problem.
 
*Check connected wires via TeltoCharge and energy meter inputs;
*Check if the energy meter is compatible;
* Check temperature.
 
|-
|-
| colspan="8" |<center><big>If issues still persists, report it via VIP helpdesk or your sales manager. ('''Note:''' please provide as much information as you can about your issue (photos, videos, etc..) this helps to solve it faster.</big></center>
| style="text-align:center;" | '''I'''
|}
| Green LEDs pulsing
 
| Initialisation of charging.
===WARNINGS===
| Normal behaviour – no action needed.
 
{| class="wikitable"
|+
|-
|-
| colspan="13" |<center><big>'''Warning message'''</big></center>
| style="text-align:center;" | '''J'''
| Green LEDs rolling upwards from the bottom
| EVC 2 is in charging process.
| Normal behaviour – no action needed.
|-
|-
|Simple CP detected
| style="text-align:center;" | '''K'''
| Temperature warning
| Green LEDs on
|Ventilation required
| EVC 2 finished charging.
|RTC time lost
| Normal behaviour – no action needed.
|Simplified CP denied
|D state denied
|Sensors not calibrated
|Energy meter comm error
|NFC init error
|Low battery voltage
|Emeter wrong type
|E-meter unidetified
| Main Board boot fail
|-
|-
| style="text-align:center;" | '''L'''
| Purple LEDs on
| EVC 2 requires ventilation (charging is done in state D).
| Open installer menu via the app and select that charging location is ventilated. To select that charger must be installed in ventilated location.
|-
|-
| colspan="13" |<center><big>'''Meaning'''</big></center>
| style="text-align:center;" | '''M'''
| Red four middle LEDs
| NFC/RFID card declined from the server.
| Check if NFC/RFID card is in a server cards whitelist.
|-
|-
|Connected EV uses Simplified charging sequence. Charging power is limited to1 Phase 10 A;
| style="text-align:center;" | '''N'''
| Green four middle LEDs
| NFC/RFID card accepted from the server.
| Normal behaviour – no action needed.
|}


|Temperature higher than warning limit, current throttling
=== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Red LED indications (errors)</span> ===
is present.


|EV requiring ventilation
{| class="wikitable" style="width:100%; text-align:center; table-layout:fixed;"
| EVSE date and time lost
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | A
|Simplified CP detected and not allowed
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | B
| EV requiring ventilation but charging location is not ventilated
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | C
|Sensors were not calibrated during HW configuration
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | D
|Energy meter communication error
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | E
|NFC initialization error
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | F
|Low battery voltage EVSE (RTC)
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | G
|Energy meter configuration mismatch
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; font-weight:500; padding:6px;" | H
|Energy meter type unidentified
|-
|Main board is failing to boot
| [[File:TeltoCharge LEDS InputVoltageError.png|center|frameless|205x205px]]
| [[File:TeltoCharge LEDS OutputVoltageCurrentError.png|center|frameless|205x205px]]
| [[File:TeltoCharge LEDS CurrentLeakageDetected.png|center|frameless|205x205px]]
| [[File:TeltoCharge LEDS ConnectivityError.png|center|frameless|205x205px]]
| [[File:TeltoCharge LEDS TemperatureError.png|center|frameless|205x205px]]
| [[File:TeltoCharge LEDS OtherErrors.png|center|frameless|205x205px]]
| [[File:TeltoCharge LEDS FaultyConnection.gif|center|frameless|205x205px]]
| [[File:Orange_LED_warning_LED.png|center|frameless|alt=|205x205px]]
|}


{| class="wikitable" style="width:100%;"
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px; width:5%;" | Ref
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Description
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Meaning
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Troubleshooting
|-
|-
| colspan="13" |<center><big>'''What to do to avoid'''</big></center>
| style="text-align:center;" | '''A'''
| First LED lit up in red
|
Input voltage error. Causes:
* Overvoltage
* Undervoltage
* Wrong wiring
|
* Check if input wiring is connected correctly;
* Measure input voltage;
* Check installer menu settings if supply voltage and voltage tolerance is in accordance with the measured input voltage.
|-
|-
| style="text-align:center;" | '''B'''
| Second LED lit up in red
|
|
Connected EV uses Simplified charging sequence. Charging power is limited. In installer menu option „Simplified charging sequence“ must be turned ON.
Output voltage/current error. Causes:
* Overvoltage
* Undervoltage
* Output current
|
|
 
* Disconnect charging cable from the EV and check if the issue remains.
* Reboot charger and try to connect EV again.
|-
| style="text-align:center;" | '''C'''
| Third LED lit up in red
| Current leakage detected.
|
|
Check if Charging location is sufficiently ventilated
* Disconnect the cable from the EV and check if the error persists.
* If the error is cleared, try to start charging. If the error occurs once again, try following steps:
* Check if charging cable is fully plugged into socket and/or EV;
* Check if the inside of both the socket and the plug has no foreign materials inside (is clean).
* Check visually if the cable is not damaged.
* Check if the boards are not covered in dust and/or other materials.
|-
| style="text-align:center;" | '''D'''
| Fourth LED lit up in red
|
|
Check EVSE RTC coin battery (CR 1220)
Connectivity error. Causes:
* Cable lock
* PP fail
* Car diode
|
|
Connected EV uses Simplified charging sequence. Simplified CP charging is disabled in Installer menu.
* Check if the charging cable is connected correctly from the charger side (socket version) and from the EV side;
* Try to reconnect charging cable to the EV and EVSE (charger) (if it is socket version).
* Listen if you can hear a clicking sound from the EVC 2 when you plug the cable to EV. Charger should lock cable plug. If you can’t hear, try to unplug cable (from EVSE (charger) side) while it is plugged from EV side. If it is possible to unplug, report this problem via VIP helpdesk or your sales manager.
* If none of these steps helps, measure the voltage between PE and PP and check if it is in accordance to the standard.
|-
| style="text-align:center;" | '''E'''
| Fifth LED lit up in red
|
|
EV requiring ventilation, but Charging location is specified as not ventilated in Installer menu.
Temperature error. Causes:
* Temperature reached 85 °C
|
|
Contact support.
* Check the temperature inside the app > Device info. If temperature is higher than 85 °C wait while charger cools down.
|-
| style="text-align:center;" | '''F'''
| Sixth LED lit up in red
|
Internal errors. Causes:
* −12 V
|
|
Check RS485 connection with external meter. Inspect cable. Check if meter is working. Make sure devices are configutated properly.
* Restart EVC 2
|-
| style="text-align:center;" | '''G'''
| All LEDs pulsing red
|
|
Reboot charger and check if the issue remains.
Faulty connection to EV. Causes:
* CP fail
|
|
Check EVSE RTC coin battery (CR 1220).
* Try reconnect charging cable from the EV side. There might be control pilot communication problem which can occur with different EV models.
|-
| style="text-align:center;" | '''H'''
| First LED lit up in orange
|
|
Connected Energy meter and configured Energy meter type in Installer menu are different.
Warning. Problems with energy meter:
* Unrecognised
* Badly set
* Communication problems
Other problems:
* Temperature
* Current
* D state
|
|
Unknown device detected. Check if the energy meter is compatible.
Go to the live data section and see what is the main problem.
|  
* Check connected wires via EVC 2 and energy meter inputs;
Reboot charger and check if the issue remains - contact support.
* Check if the energy meter is compatible;
* Check temperature.
|}
 
<div style="border-left:4px solid; padding:4px 16px; margin:16px 0;">
If the issue persists, report it via VIP Helpdesk or your sales manager. Please provide as much information as possible (photos, videos, etc.), as this helps solve it faster.
</div>
 
=== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Warnings</span> ===
 
{| class="wikitable" style="width:100%;"
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Warning message
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Meaning
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Troubleshooting
|-
|-
| colspan="13" |<center><big>This LED shows that there is an active warning in the charger. This warning indication will work with other indications.  If issues still persists, report it via VIP helpdesk or your sales manager. ('''Note:''' please provide as much information as you can about your issue (photos, videos, etc..) this helps to solve it faster.</big></center>
| '''Simple CP detected'''
| Connected EV uses Simplified charging sequence. Charging power is limited to 1 Phase 10 A;
| Connected EV uses Simplified charging sequence. Charging power is limited. In installer menu option „Simplified charging sequence“ must be turned ON.
|-
|-
| '''Temperature warning'''
| Temperature higher than warning limit, current throttling is present.
|Charging will continue at a reduced rate.
|-
| '''Ventilation required'''
| EV requiring ventilation
| Check if Charging location is sufficiently ventilated.
|-
| '''RTC time lost'''
| EVSE (charger) date and time lost
| Check EVSE (charger) RTC coin battery (CR1220).
|-
| '''Simplified CP denied'''
| Simplified CP detected and not allowed
| Connected EV uses Simplified charging sequence. Simplified CP charging is disabled in Installer menu.
|-
| '''D state denied'''
| EV requiring ventilation but charging location is not ventilated
| EV requiring ventilation, but Charging location is specified as not ventilated in Installer menu.
|-
| '''Sensors not calibrated'''
| Sensors were not calibrated during HW configuration
| Contact support.
|-
| '''Energy meter comm error'''
| Energy meter communication error
| Check RS485 connection with external meter. Inspect cable. Check if meter is working. Make sure devices are configured properly.
|-
| '''NFC init error'''
| NFC initialisation error
| Reboot charger and check if the issue remains.
|-
| '''Low battery voltage'''
| Low battery voltage EVSE (charger) (RTC)
| Check EVSE (charger) RTC coin battery (CR1220).
|-
| '''Emeter wrong type'''
| Energy meter configuration mismatch
| Connected Energy meter and configured Energy meter type in Installer menu are different.
|-
| '''E-meter unidentified'''
| Energy meter type unidentified
| Unknown device detected. Check if the energy meter is compatible.
|-
| '''Main Board boot fail'''
| Main board is failing to boot
| Reboot charger and check if the issue remains - contact support.
|}
|}


[[Category: Product guides]]
<div style="border-left:4px solid; padding:4px 16px; margin:16px 0;">
These warning LEDs show that there is an active warning in the charger. This warning indication will work with other indications. If the issue persists, report it via VIP Helpdesk or your sales manager. Please provide as much information as possible (photos, videos, etc.), as this helps solve it faster.
</div>
 
</div>
[[Category:Main Page EVC2]]

Latest revision as of 09:18, 28 October 2026

Main Page > Main Page EVC2 > Troubleshooting Guide EVC2

Introduction

This page provides troubleshooting information for EVC 2.

What to do first when an issue occurs

Most issues can be solved with the following steps:

  1. Update the mobile app to the latest version via Google Play or the App Store.
  2. In your charger settings, update the charger firmware to the latest version (see the firmware update guide).
  3. Reboot the device from the charger settings.

How to check the charger firmware version

Follow these steps to check your current EVC 2 firmware version in the app and update it. Always make sure your charger has the latest firmware.

  1. Go to the app settings and press Device info.
  2. Press Check for updates.
  3. The current firmware version is shown at the top.

How to download the troubleshoot file

Follow these steps to download the troubleshoot file in the app.

  1. Go to Diagnostics.
  2. Scroll to the bottom.
  3. Tap Troubleshoot file.
  4. Tap Download troubleshoot file.
  5. Wait for the ‘file downloaded’ message.
  6. Select the downloaded file.
  7. Tap the icon in the top right corner and press Share.

Note: For best results, download the file during a charging session, so that more details about the current situation are saved.

LED indicators

Status indications

A B C D E F G
H I J K L M N
Ref Description Meaning Troubleshooting
A White LEDs rolling from the bottom to the top EVC 2 is booting up. Normal behaviour – no action needed.
B White LEDs rolling from the top to the bottom EVC 2 is Reserved (OCPP only). Normal behaviour – no action needed.
C White pulsing LEDs EVC 2 is in standby mode and waiting for action. Normal behaviour – no action needed.
D Yellow LEDs on EVC 2 is not charging, simplified charging sequence is required. Open installer menu via the app and select to allow simplified charging sequence.
E Blue LEDs lights up from the middle EVC 2 do not require permission, it is waiting for EV to initiate charging process (go to state C). Normal behaviour – no action needed.
F Blue LEDs pulsing Permission to charge is not granted. EVC 2 requires authorisation. Authorise yourself with app or NFC card.
G Blue LEDs rolldown from up to down
  1. Wait for scheduled time.
  2. No dynamic power – DLB/DLM/Solar enabled and no sufficient power.
  3. EVSE (charger) suspended.
  4. Reserved charge (OCPP only).
  1. Go to settings via the app and select schedule time section to check for set graphs
  2. Wait for more available power or increase amperage limits via settings (if your grid allows it)
  3. Available power is less than 6 A. Provide more power or wait for more to generate.
  4. Other user has already reserved this charging station or RemoteStartTransaction command was received (OCPP only)
H Four middle blue LEDs pulsing EVC 2 waiting to add new NFC card. Normal behaviour – no action needed.
I Green LEDs pulsing Initialisation of charging. Normal behaviour – no action needed.
J Green LEDs rolling upwards from the bottom EVC 2 is in charging process. Normal behaviour – no action needed.
K Green LEDs on EVC 2 finished charging. Normal behaviour – no action needed.
L Purple LEDs on EVC 2 requires ventilation (charging is done in state D). Open installer menu via the app and select that charging location is ventilated. To select that charger must be installed in ventilated location.
M Red four middle LEDs NFC/RFID card declined from the server. Check if NFC/RFID card is in a server cards whitelist.
N Green four middle LEDs NFC/RFID card accepted from the server. Normal behaviour – no action needed.

Red LED indications (errors)

A B C D E F G H
Ref Description Meaning Troubleshooting
A First LED lit up in red

Input voltage error. Causes:

  • Overvoltage
  • Undervoltage
  • Wrong wiring
  • Check if input wiring is connected correctly;
  • Measure input voltage;
  • Check installer menu settings if supply voltage and voltage tolerance is in accordance with the measured input voltage.
B Second LED lit up in red

Output voltage/current error. Causes:

  • Overvoltage
  • Undervoltage
  • Output current
  • Disconnect charging cable from the EV and check if the issue remains.
  • Reboot charger and try to connect EV again.
C Third LED lit up in red Current leakage detected.
  • Disconnect the cable from the EV and check if the error persists.
  • If the error is cleared, try to start charging. If the error occurs once again, try following steps:
  • Check if charging cable is fully plugged into socket and/or EV;
  • Check if the inside of both the socket and the plug has no foreign materials inside (is clean).
  • Check visually if the cable is not damaged.
  • Check if the boards are not covered in dust and/or other materials.
D Fourth LED lit up in red

Connectivity error. Causes:

  • Cable lock
  • PP fail
  • Car diode
  • Check if the charging cable is connected correctly from the charger side (socket version) and from the EV side;
  • Try to reconnect charging cable to the EV and EVSE (charger) (if it is socket version).
  • Listen if you can hear a clicking sound from the EVC 2 when you plug the cable to EV. Charger should lock cable plug. If you can’t hear, try to unplug cable (from EVSE (charger) side) while it is plugged from EV side. If it is possible to unplug, report this problem via VIP helpdesk or your sales manager.
  • If none of these steps helps, measure the voltage between PE and PP and check if it is in accordance to the standard.
E Fifth LED lit up in red

Temperature error. Causes:

  • Temperature reached 85 °C
  • Check the temperature inside the app > Device info. If temperature is higher than 85 °C wait while charger cools down.
F Sixth LED lit up in red

Internal errors. Causes:

  • −12 V
  • Restart EVC 2
G All LEDs pulsing red

Faulty connection to EV. Causes:

  • CP fail
  • Try reconnect charging cable from the EV side. There might be control pilot communication problem which can occur with different EV models.
H First LED lit up in orange

Warning. Problems with energy meter:

  • Unrecognised
  • Badly set
  • Communication problems

Other problems:

  • Temperature
  • Current
  • D state

Go to the live data section and see what is the main problem.

  • Check connected wires via EVC 2 and energy meter inputs;
  • Check if the energy meter is compatible;
  • Check temperature.

If the issue persists, report it via VIP Helpdesk or your sales manager. Please provide as much information as possible (photos, videos, etc.), as this helps solve it faster.

Warnings

Warning message Meaning Troubleshooting
Simple CP detected Connected EV uses Simplified charging sequence. Charging power is limited to 1 Phase 10 A; Connected EV uses Simplified charging sequence. Charging power is limited. In installer menu option „Simplified charging sequence“ must be turned ON.
Temperature warning Temperature higher than warning limit, current throttling is present. Charging will continue at a reduced rate.
Ventilation required EV requiring ventilation Check if Charging location is sufficiently ventilated.
RTC time lost EVSE (charger) date and time lost Check EVSE (charger) RTC coin battery (CR1220).
Simplified CP denied Simplified CP detected and not allowed Connected EV uses Simplified charging sequence. Simplified CP charging is disabled in Installer menu.
D state denied EV requiring ventilation but charging location is not ventilated EV requiring ventilation, but Charging location is specified as not ventilated in Installer menu.
Sensors not calibrated Sensors were not calibrated during HW configuration Contact support.
Energy meter comm error Energy meter communication error Check RS485 connection with external meter. Inspect cable. Check if meter is working. Make sure devices are configured properly.
NFC init error NFC initialisation error Reboot charger and check if the issue remains.
Low battery voltage Low battery voltage EVSE (charger) (RTC) Check EVSE (charger) RTC coin battery (CR1220).
Emeter wrong type Energy meter configuration mismatch Connected Energy meter and configured Energy meter type in Installer menu are different.
E-meter unidentified Energy meter type unidentified Unknown device detected. Check if the energy meter is compatible.
Main Board boot fail Main board is failing to boot Reboot charger and check if the issue remains - contact support.

These warning LEDs show that there is an active warning in the charger. This warning indication will work with other indications. If the issue persists, report it via VIP Helpdesk or your sales manager. Please provide as much information as possible (photos, videos, etc.), as this helps solve it faster.