Jump to content

Functionalities EVC2: Difference between revisions

From Teltonika Energy Wiki
 
(11 intermediate revisions by 2 users not shown)
Line 6: Line 6:
# Three phase No neutral
# Three phase No neutral
='''NEW:''' Physical power selector switch=
='''NEW:''' Physical power selector switch=
* This switch could be found on the interface board.   
* This switch is found on the interface board.   
* It could turned to to limit MAX device output. By changing rotary switch position it is possible to charge charger’s max output.   
* It could be turned to limit MAX device output. By changing rotary switch position it is possible to charge charger’s max output.   
* By default (position 0) charger sets max possible output power depending on HW.  
* By default (position 0) charger sets max possible output power depending on HW.  
* Possible values differ between different modification devices.[[File:Power selector switch.png|thumb|none]]
* Possible values differ between different modification devices.[[File:Power selector switch.png|thumb|none]]
Line 35: Line 35:
| Reserved || 9 || N/A || N/A || N/A
| Reserved || 9 || N/A || N/A || N/A
|}
|}
='''NEW:''' IT grid support=
Enable this setting if the charger is installed on an IT grid. <br>
When turned on, the charging station adapts its voltage monitoring for IT grid operation, where voltage can be floating in relation to protective earth (PE).
='''NEW:''' Button switch=
='''NEW:''' Button switch=
This switch could be found on the interface board, It has 2 features:  
This switch could be found on the interface board, It has 2 features:  
Line 120: Line 125:
If the EV charging process is interrupted (e. g. temporary power outage), the randomized delay will still be in effect when the power is restored, further delaying the start of charging.<br>
If the EV charging process is interrupted (e. g. temporary power outage), the randomized delay will still be in effect when the power is restored, further delaying the start of charging.<br>


When OCPP is turned on, the Randomized delay functionality will not be active.
The maximum value for Randomized Delay can be set to up to 30 minutes if needed.


= Errors and warnings =
= Errors and warnings =
Line 264: Line 269:


''By Default this setting is turned off''<br>
''By Default this setting is turned off''<br>
''Not available in North America products''


== Automatic energy meter type search ==
== Automatic energy meter type search ==
Line 289: Line 293:
„EV Sleep“ feature prevents the charger from repeatedly waking up and restarting when the electric vehicle does not actually begin charging. Some EVs (Electric Vehicles) trigger repeated B2 → D1 → B2 cycles, which can cause unnecessary start attempts. When enabled, this feature protects the charger from entering this loop.
„EV Sleep“ feature prevents the charger from repeatedly waking up and restarting when the electric vehicle does not actually begin charging. Some EVs (Electric Vehicles) trigger repeated B2 → D1 → B2 cycles, which can cause unnecessary start attempts. When enabled, this feature protects the charger from entering this loop.


How the feature works <br>
'''How the feature works''' <br>
When EV Sleep Mode is disabled (Default): <br>
''When EV Sleep Mode is disabled (Default):'' <br>
The charger behaves normally and does not block the repeated B2/D1 sequence.<br>
The charger behaves normally and does not block the repeated B2/D1 sequence.<br>
If the EV stops charging and then requests the charger again, the EVSE will always try to restart charging.<br>
If the EV stops charging and then requests the charger again, the EVSE will always try to restart charging.<br>
Recommended for users who rely on DLM / Smart Charging and want continuous restart attempts.<br>
Recommended for users who rely on DLM / Smart Charging and want continuous restart attempts.<br>
<br>
<br>
When EV Sleep Mode is enabled:<br>
''When EV Sleep Mode is enabled:''<br>
The charger starts tracking how many times it enters the sequence:<br>
The charger starts tracking how many times it enters the sequence:<br>
C (charging) → B2 (EV stopped) → D1 (waiting) → B2 → …<br>
C (charging) → B2 (EV stopped) → D1 (waiting) → B2 → …<br>
Line 305: Line 309:
The counter resets automatically when the EV successfully starts charging after this sequence.
The counter resets automatically when the EV successfully starts charging after this sequence.


Who should enable this feature?
'''Who should enable this feature?''' <br>
This mode is recommended if: <br>
This mode is recommended if: <br>
1. The user experiences repeated interrupted cycles (stop → wait → start attempt). <br>
1. The user experiences repeated interrupted cycles (stop → wait → start attempt). <br>

Latest revision as of 15:20, 19 October 2026

Main Page > TeltoCharge > Product guides > Functionalities EVC2