Difference between revisions of "Dynamic load balancing FAQ"

From Wiki
(Created page with "{| class="wikitable" |No. |'''Question''' |'''Answer''' |- |1. | | |- |2. | | |- |3. | | |- |4. | | |- |5. | | |}")
(9 intermediate revisions by 3 users not shown)
Line 5: Line 5:
 
|-
 
|-
 
|1.
 
|1.
|How TeltoCharge sets maximum charging power when 3-phase charging is enabled?
+
|
|TeltoCharge checks which phase is loaded most, measures how much free current is available, and sets that current.
+
|
 
|-
 
|-
 
|2.
 
|2.
|Can I use simplified charging sequence with Dynamic load balancing.
+
|
|Yes, there is possibility to use both features together, but there are some limitations which are regulated by the standard (IEC 61851-1 / SAE J1772):
+
|
 
 
# Maximum charging current is only 10 Ampers.
 
# Possible to use only 1-phase charging.
 
 
|-
 
|-
 
|3.
 
|3.
|Can I use 3-phase smart meter for single phase charger?
+
|
|Yes, there is possibility to use 1-phase charger with 3-phase smart meter. Please refer to the Energy meter instruction sheet to configure it properly. It is required to select single phase meter in the TeltoCharge application settings.
+
|
 
|-
 
|-
 
|4.
 
|4.
|Does Load balancing limits Dynamic load balancing?
+
|
|Yes, if dynamic load balancing is enabled and user want to achieve maximum charging power without any other limitations except form smart energy meter. [https://wiki.teltonika-energy.com/view/Functionalities#Load_balancing Load balancing] should be set to the maximum value.
+
|
 
|-
 
|-
 
|5.
 
|5.
|If "''use preferred phase''" is enabled, can charger automatically change phase?
+
|
|Yes, If TeltoCharge detects that prioritized phase is loaded and the maximum current it can give is 7 or less ampers, charger will make a check If other phases are loaded less:
+
|
 
 
* If there is other phase which is loaded less, charger will change charging phase.
 
* If other two phases are loaded as well, charger will stop charging process.
 
|-
 
|6.
 
|How TeltoCharge prioritizes phases when phase priority is disabled, TeltoChagre connected to three phases and three phase charging is disabled? [[/]]
 
|Charger checks which phase is least loaded and selects that phase as a charging phase. If during charging process any of other two phases load decreases and the maximum available current will be 5 amperes higher then the charging phase, TeltoCharge will change charging phase to the least loaded. [[1]]
 
 
|}
 
|}

Revision as of 08:35, 1 July 2022