Jump to content

Release notes: Firmware: Difference between revisions

From Teltonika Energy Wiki
No edit summary
No edit summary
 
(5 intermediate revisions by the same user not shown)
Line 15: Line 15:
|
|
* Fixed secondary Modbus devices sometimes not taking on new data passed from the primary.
* Fixed secondary Modbus devices sometimes not taking on new data passed from the primary.
* Fixed solar modes not working correctly via DLM TCP.
* Fixed solar related charging data not being observed when DLM TCP is used.
* Fixed secondary TCP device timeout configuration not applying correctly from the app or external control.
* Fixed secondary TCP device timeout configuration not applying correctly from the app or external control.
* Fixed wrong error code appearing if a status notification is triggered while a warning is already displayed.
* Fixed wrong error code appearing if a status notification is triggered while a warning is already displayed.
* Fixed load balancing resetting to 10A upon changing the product code.
* Fixed maximum current exceeding grid maximum in particular DLB configurations.
* Fixed maximum current exceeding grid maximum in particular DLB configurations.
* Fixed Wi-Fi connection issues after charger reboot.
* Fixed an issue with eSim charger connectivity after reboot.
|}
|}
== Previous Firmware versions ==
== Previous Firmware versions ==

Latest revision as of 12:09, 13 August 2026

Latest Firmware Version

Version Date New features and settings Bug fixes and improvements
EVC2xx V2.3.0 2026.08.10
  • Added control over solar power, charging modes, randomized delay and scheduling settings when OCPP is enabled.
  • Simplified the Diagnostics Voltage fields for 1-phase chargers.
  • Added functionality to increasee maximum randomized delay duration up to 30 minutes.
  • Added the option to adjust randomized delay through external means such as secondary DLM devices or the app via ESP.
  • Fixed secondary Modbus devices sometimes not taking on new data passed from the primary.
  • Fixed solar modes not working correctly via DLM TCP.
  • Fixed solar related charging data not being observed when DLM TCP is used.
  • Fixed secondary TCP device timeout configuration not applying correctly from the app or external control.
  • Fixed wrong error code appearing if a status notification is triggered while a warning is already displayed.
  • Fixed maximum current exceeding grid maximum in particular DLB configurations.
  • Fixed Wi-Fi connection issues after charger reboot.
  • Fixed an issue with eSim charger connectivity after reboot.

Previous Firmware versions

Version Date New features and settings Bug fixes and improvements
EVC2xx V2.2.8 2026.06.18
  • Improved connectivity to remote management system.
EVC2xx V2.2.7 2026.06.04
  • Fixed OCPP wrong StatusNotification errorCode after trigger
  • Fixed troubleshoot file high/low voltage naming
  • Fixed 3phase delta grid failing to check input voltage
EVC2xx V2.2.6 2026.05.01
  • Added new solar charging modes for Dynamic Load Management, including Solar Only, ECO, and Hybrid modes.
  • Added new Dynamic Load Management capabilities, including potential-free contact support, dynamic IP device discovery and reconnection, and configurable 1-phase charging behavior.
  • Expanded Modbus meter support with additional Eastron and ABB meter models.
  • Added installer setting for IT grid voltage sampling.
  • Added an NFC reader cooldown to prevent accidental repeated actions.
  • Improved charging session recovery, troubleshooting logs, and reboot reporting after power loss events.
  • Improved solar charging and Dynamic Load Management stability, including power limit handling, Modbus TCP communication, ECO mode synchronization, and DLM failsafe behavior.
  • Improved communication stability for Bluetooth, LAN, and WebSocket connections.
  • Improved charging session energy graph accuracy and HomeWizard P1 meter data handling.
  • Improved OCPP configuration request handling and tamper event reporting.
  • Improved internal time synchronization.
EVC2xx V2.1.5 2026.01.06
  • UK product code handling
  • NFC scanning module improvements
  • Fixed bugs where the settings were not being saved while switching power selector
  • Improved OCPP handling when starting/stopping charge
  • Various bug fixes related to parameter and information handling
EVC2xx V2.1.0 2025.11.24
  • Support for Shelly 3PRO meters added
  • Modbus TCP device control enabled
  • New settings: Max group load & Max grid load for DLM/DLB functions
  • 2x RS-485 port support
  • EVC2XX potential-free contact support
  • Power rotary switch implementation for easier setup
  • Automatic grid type detection and phase rotation support
  • LAN-based device control via EV charging app, previously it was possible through Bluetooth only
  • Automatic firmware updates support
  • Changed installer menu code to 4 digits
  • Various metering and charging bug fixes
  • Various Modbus and OCPP communication protocol enhancements
  • Charger stability issues resolved
  • Bluetooth, NFC and UI features improved

Updating

Use our app to update the station manually

  1. Use app and go to settings, scroll down and press Device info;
  2. Press Check for updates;
  3. At the top, current firmware version can be found.
  4. User has 2 options: to update from our cloud or by manually uploading a firmware file to the charger.