Line 21: Line 21:
 
| style="padding: 2px;" | +
 
| style="padding: 2px;" | +
 
| style="padding: 2px;" | 3 phases
 
| style="padding: 2px;" | 3 phases
| style="padding: 2px;" | CT (6 Amps)
+
| style="padding: 2px;" | Direct
 
| style="padding: 2px;" | NA
 
| style="padding: 2px;" | NA
 
| style="padding: 2px;" | [https://chintglobal.com/products/dtsu666-three-phase-din-rail-meter-8-1007 DTSU 666]
 
| style="padding: 2px;" | [https://chintglobal.com/products/dtsu666-three-phase-din-rail-meter-8-1007 DTSU 666]
Line 31: Line 31:
 
| style="padding: 2px;" | +
 
| style="padding: 2px;" | +
 
| style="padding: 2px;" | 1 phase
 
| style="padding: 2px;" | 1 phase
| style="padding: 2px;" | CT (6 Amps)
+
| style="padding: 2px;" | Direct
 
| style="padding: 2px;" | NA
 
| style="padding: 2px;" | NA
 
| style="padding: 1px;" | [https://chintglobal.com/products/ddsu666-single-phase-din-rail-meter-8-1004 DDSU 666]
 
| style="padding: 1px;" | [https://chintglobal.com/products/ddsu666-single-phase-din-rail-meter-8-1004 DDSU 666]
 +
|-
 +
|Chint
 +
|DTSU
 +
666-CT
 +
|230V/400V
 +
|Yes
 +
|Yes
 +
| +
 +
|3
 +
phases
 +
|CT
 +
|NA
 +
|[https://store.klinkmann.com/wp-content/uploads/2023/10/manual-DTSSU666.pdf DTSU]
 +
[https://store.klinkmann.com/wp-content/uploads/2023/10/manual-DTSSU666.pdf 666]
 +
 
|}
 
|}
 
+
<p style="color: red"> '''''Note: CHINT DTSU666-H is not supported at the moment''''' </p>
==== Chint meters wiring: ====
+
<p style="color: red"> '''''Note: CHINT DTSU666-CT, that has "X" on their label is not supported at the moment''''' </p>
 
+
====Chint meters wiring:====
 +
[[File:Chint_meter_(1).png|alt=|center|frame]]
  
  
==== Powering the energy meter ====
+
====Powering the energy meter====
 
To correctly connect smart energy meter to power source:
 
To correctly connect smart energy meter to power source:

Latest revision as of 09:17, 18 November 2024

Smart energy meters

Chint smart energy meters technical information

Energy meter manufacturer Type Power supply (V) Supported model for DLB* Supported model for Solar* MID certified 1/3 phase Connection Direct Connection Rating Value Datasheet
Chint DTSU 666
380 V Yes Yes + 3 phases Direct NA DTSU 666
DDSU 666
230 V Yes Yes + 1 phase Direct NA DDSU 666
Chint DTSU

666-CT

230V/400V Yes Yes + 3

phases

CT NA DTSU

666

Note: CHINT DTSU666-H is not supported at the moment

Note: CHINT DTSU666-CT, that has "X" on their label is not supported at the moment

Chint meters wiring:


Powering the energy meter