WARNINGS

Warning message
Simple CP detected Temperature warning Ventilation required RTC time lost Simplified CP denied D state denied Sensors not calibrated Energy meter comm error NFC init error Low battery voltage Emeter wrong type E-meter unidetified Main Board boot fail
Meaning
Connected EV uses Simplified charging sequence. Charging power is limited to1 Phase 10 A; Temperature higher than warning limit, current throttling

is present.

EV requiring ventilation EVSE date and time lost Simplified CP detected and not allowed EV requiring ventilation but charging location is not ventilated Sensors were not calibrated during HW configuration Energy meter communication error NFC initialization error Low battery voltage EVSE (RTC) Energy meter configuration mismatch Energy meter type unidentified Main board is failing to boot
What to do to avoid

Connected EV uses Simplified charging sequence. Charging power is limited. In installer menu option „Simplified charging sequence“ must be turned ON.

Check if Charging location is sufficiently ventilated

Check EVSE RTC coin battery (CR 1220)

Connected EV uses Simplified charging sequence. Simplified CP charging is disabled in Installer menu.

EV requiring ventilation, but Charging location is specified as not ventilated in Installer menu.

Contact support.

Check RS485 connection with external meter. Inspect cable. Check if meter is working. Make sure devices are configutated properly.

Reboot charger and check if the issue remains.

Check EVSE RTC coin battery (CR 1220).

Connected Energy meter and configured Energy meter type in Installer menu are different.

Unknown device detected. Check if the energy meter is compatible.

Reboot charger and check if the issue remains - contact support.

This LED shows that there is an active warning in the charger. This warning indication will work with other indications. If issues still persists, report it via VIP helpdesk or your sales manager. (Note: please provide as much information as you can about your issue (photos, videos, etc..) this helps to solve it faster.