Difference between revisions of "EM and ET models"

From Wiki
 
(8 intermediate revisions by the same user not shown)
Line 15: Line 15:
 
| style="padding: 2px;" rowspan="4" | EM111 <br>
 
| style="padding: 2px;" rowspan="4" | EM111 <br>
 
| style="padding: 1px;" | 120 V
 
| style="padding: 1px;" | 120 V
| colspan="2" style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/archive/b/b7/20230306130515%21EM111.PNG EM111-DIN AV7 1 X S1 PF A/B]
+
| colspan="2" style="padding: 2px;" |[https://wiki.teltonika-energy.com/images/7/71/EM111_Solar.PNG EM111-DIN AV7 1 X S1 PF B]
 
| style="padding: 1px;" | +
 
| style="padding: 1px;" | +
 
| rowspan="10" style="padding: 2px;" | 1 phase <br>
 
| rowspan="10" style="padding: 2px;" | 1 phase <br>
Line 22: Line 22:
 
|-
 
|-
 
| style="padding: 2px;" | 230 V
 
| style="padding: 2px;" | 230 V
| colspan="2" style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/b/b7/20230306130515%21EM111.PNG EM111-DIN AV8 1 X S1 PF A/B]
+
| colspan="2" style="padding: 1px;" |[https://wiki.teltonika-energy.com/images/7/71/EM111_Solar.PNG EM111-DIN AV8 1 X S1 PF B]
 
| style="padding: 1px;" | +
 
| style="padding: 1px;" | +
 
|-
 
|-
Line 35: Line 35:
 
| rowspan="4" |EM112
 
| rowspan="4" |EM112
 
|120 V
 
|120 V
|
+
| colspan="2" style="padding: 2px;" |[https://wiki.teltonika-energy.com/images/b/b2/EM112_Solar.PNG EM112-DIN AV1 1 X S1 PF B]
|
 
 
| +
 
| +
| rowspan="4" |
+
| rowspan="4" style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM112DS.pdf EM112]
 
|-
 
|-
 
|230 V
 
|230 V
|
+
| colspan="2" style="padding: 2px;" |[https://wiki.teltonika-energy.com/images/b/b2/EM112_Solar.PNG EM112-DIN AV0 1 X S1 PF B]
|
 
 
| +
 
| +
 
|-
 
|-
 
|120 V
 
|120 V
|
+
| colspan="2" style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/8/81/EM112_Standard.PNG EM112-DIN AV1 1 X S1 X]
|
 
 
| -
 
| -
 
|-
 
|-
 
|230 V
 
|230 V
|
+
| colspan="2" style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/8/81/EM112_Standard.PNG EM112-DIN AV0 1 X S1 X]
|
 
 
| -
 
| -
 
|-
 
|-
Line 83: Line 79:
 
| style="padding: 2px;" rowspan="2" | EM340 <br>
 
| style="padding: 2px;" rowspan="2" | EM340 <br>
 
| style="padding: 1px;" | 400 V
 
| style="padding: 1px;" | 400 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/a/a6/20230306130731%21EM340.PNG EM340-DIN AV2 3 X S1 PF A/B]
+
| colspan="2" style="padding: 1px;" |[https://wiki.teltonika-energy.com/images/f/f8/EM340_Solar.PNG EM340-DIN AV2 3 X S1 PFB]
| style="padding: 1px;" |
 
 
| style="padding: 1px;" | +
 
| style="padding: 1px;" | +
 
| style="padding: 2px;" rowspan="2" | [https://www.gavazzi.no/wp-content/uploads/EM340_DS_ENG.pdf EM340]
 
| style="padding: 2px;" rowspan="2" | [https://www.gavazzi.no/wp-content/uploads/EM340_DS_ENG.pdf EM340]
Line 117: Line 112:
 
| style="padding: 2px;" | EM530  
 
| style="padding: 2px;" | EM530  
 
| style="padding: 2px;" | 400 V
 
| style="padding: 2px;" | 400 V
| style="padding: 2px;" |
+
| style="padding: 2px;" | Yes
| style="padding: 2px;" |  
+
| style="padding: 2px;" | Yes
 
| style="padding: 1px;" | +
 
| style="padding: 1px;" | +
 
| style="padding: 2px;" rowspan="2" | 3 phase
 
| style="padding: 2px;" rowspan="2" | 3 phase
Line 125: Line 120:
 
| style="padding: 2px;" | EM540  
 
| style="padding: 2px;" | EM540  
 
| style="padding: 2px;" | 400 V
 
| style="padding: 2px;" | 400 V
| style="padding: 2px;" |  
+
| style="padding: 2px;" | Yes
| style="padding: 2px;" |  
+
| style="padding: 2px;" | Yes
 
| style="padding: 1px;" | +
 
| style="padding: 1px;" | +
 
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM540_DS_ENG.pdf EM540]
 
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM540_DS_ENG.pdf EM540]
Line 132: Line 127:
  
 
'''''*DLB''' - Dynamic load balancing''
 
'''''*DLB''' - Dynamic load balancing''
 
 
  
 
==== Carlo Gavazzi meters wiring: ====
 
==== Carlo Gavazzi meters wiring: ====

Latest revision as of 13:12, 5 June 2024

Carlo Gavazzi smart energy meters technical information

Energy meter manufacturer Type Power supply (V) Supported model for DLB* Supported model for Solar MID certified 1/3 phase Datasheet
Carlo Gavazzi series 1 EM111
120 V EM111-DIN AV7 1 X S1 PF B + 1 phase
EM111
230 V EM111-DIN AV8 1 X S1 PF B +
120 V EM111-DIN AV7 1 X S1 X -
230 V EM111-DIN AV8 1 X S1 X -
EM112 120 V EM112-DIN AV1 1 X S1 PF B + EM112
230 V EM112-DIN AV0 1 X S1 PF B +
120 V EM112-DIN AV1 1 X S1 X -
230 V EM112-DIN AV0 1 X S1 X -
ET112
120 V ET112-DIN AV1 1 X S1 X - ET112
230 V ET112-DIN AV0 1 X S1 X -
Carlo Gavazzi series 3 EM330
400 V EM330-DIN AV5 3 H S1 PF A/B + 3 phase EM330
400 V EM330-DIN AV5 3 H S1 X -
EM340
400 V EM340-DIN AV2 3 X S1 PFB + EM340
400 V EM340-DIN AV2 3 X S1 X -
ET330
230 V ET330-DIN AV5 3 H S1 X - 1 phase ET330
400 V ET330-DIN AV5 3 H S1 X - 3 phase
ET340 400 V ET340-DIN AV2 3 X S1 X - ET340
Carlo Gavazzi series 5 EM530 400 V Yes Yes + 3 phase EM530
EM540 400 V Yes Yes + EM540

*DLB - Dynamic load balancing

Carlo Gavazzi meters wiring:

Note 1: All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory.
Note 2: Ensure that the power is off before proceeding with the wiring


1st series to TeltoCharge connection
TeltoCharge DLB CarloGavazzi 1phase.png
3rd and 5th series to TeltoCharge connection
TeltoCharge DLB CarloGavazzi 3phase.png

Powering the energy meter

To correctly connect smart energy meter to power source, it is recommended to use manufacturers installation manuals.


Smart energy meters