Difference between revisions of "Electrical Specifications"

From Wiki
Line 19: Line 19:
 
|16 A
 
|16 A
 
|32 A
 
|32 A
|-
 
|Max power on single phase
 
|7.4 kW
 
|3.7 kW
 
|7.4 kW
 
|-
 
|Max power on three phase
 
|Not applicable
 
|11 kW
 
|22 kW
 
 
|-
 
|-
 
| rowspan="2" |Input voltage
 
| rowspan="2" |Input voltage

Revision as of 12:46, 3 October 2023

Main Page > TeltoCharge > General information > Electrical Specifications

TeltoCharge have different configurations, which can be customizable to suit user needs.


AC INPUT SPECIFICATIONS
EVC10X 7,4 kW EVC11X 11 kW EVC12X 22 kW
Input AC power connection 1 phase 1 or 3 phases 1 or 3 phases
Maximum current 32 A 16 A 32 A
Input voltage (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT II
Protection against electric shock Class I
AC Output specifications
AC output voltage range (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Connection Standart Type 2 cable

Type 2 socket

Power Cable
Maximum cable diameter 17.5 mm
Maximum wire cross section 7.5 mm2