Release note FW 1.9.5
To get the latest features and bug fixes, please update your charger's firmware and Android/iOS app to latest version (v1.9.0)
New features
Application in multiple languages
From now on, TeltoCharge application interface can be represented in 11 different languages.
List of included languages:
- English
- Lithuanian
- French
- Spanish
- Italian
- German
- Russian
- Turkish
- Portuguese
- Polish
- Arabic
NOTE:
Language can be changed only in station selection window
Improvements
Timer for buzzer
From this FW version, in case error buzzer is activated, signaling noise will be stopped after 15 seconds.
Notification in red light LEDs on product and in mobile application will remain ON.
Default section Peak hours adjustement
In products EVC16/161, Default hours settings will be enabled during first time setup.
In other product families, Default hours settings will be disabled.
NOTE:
This setting can be changed anytime in Schedule section
Solar feature expansion
Teltocharge Solar charging feature will be available in households with grids that do not use neutral wire (Belgium, North America, etc.)
EVC13 product family supports only single phase meters.
Solar feature support with CT clamps
From now on Teltocharge EVC160/EVC161 will allow users to use Solar charging functionality by installing CT clamps in the grid.
It is now possible to choose what to use according to convenience:
- Energy meters
- CT clamps
LED indicators with OCPP enabled optimization
LED indication added to notify when RemoteStartTransaction command is received.
LEDs indication will be the same as when charger is reserved.
Solar charging feature logic adjusted
With this firmware release, Solar charging logic will include these additions:
- When charging is stopped with NFC or App and new charging mode is selectedfrom dropdown list - charging automatically starts by using selected mode.
- When authorization is required to start charging and new charging mode isselected from dropdown list - charging automatically starts by using selectedmode.
- When authorization is required to start charging and main slider or NFC is usedto authorize - charging automatically starts by using default mode.
- When charging is stopped with NFC or App and main slider is used to startcharging again - charging automatically starts by using default mode.
New error codes in OCPP
New error codes include:
- EVCommunicationError
- OverVoltage
- PowerMeterFailure
- UnderVoltage
These codes are sent on according Fault state if triggered.
Fixes
APP
- Performance optimization
FW
- LED indications optimization
- Timer stabilization
- Minor optimization