Difference between revisions of "EM and ET models"
From Wiki
(2 intermediate revisions by the same user not shown) | |||
Line 15: | Line 15: | ||
| style="padding: 2px;" rowspan="4" | EM111 <br> | | style="padding: 2px;" rowspan="4" | EM111 <br> | ||
| style="padding: 1px;" | 120 V | | style="padding: 1px;" | 120 V | ||
− | | | + | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/archive/b/b7/20230306130515%21EM111.PNG EM111-DIN AV7 1 X S1 PF A/B] |
+ | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/7/71/EM111_Solar.PNG EM111-DIN AV7 1 X S1 PF B] | ||
| style="padding: 1px;" | + | | style="padding: 1px;" | + | ||
| rowspan="10" style="padding: 2px;" | 1 phase <br> | | rowspan="10" style="padding: 2px;" | 1 phase <br> | ||
Line 22: | Line 23: | ||
|- | |- | ||
| style="padding: 2px;" | 230 V | | style="padding: 2px;" | 230 V | ||
− | | | + | | style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/b/b7/20230306130515%21EM111.PNG EM111-DIN AV8 1 X S1 PF A/B] |
+ | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/7/71/EM111_Solar.PNG EM111-DIN AV8 1 X S1 PF B] | ||
| style="padding: 1px;" | + | | style="padding: 1px;" | + | ||
|- | |- | ||
Line 35: | Line 37: | ||
| rowspan="4" |EM112 | | rowspan="4" |EM112 | ||
|120 V | |120 V | ||
− | | | + | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/f/f6/EM112.PNG EM112-DIN AV1 1 X S1 PF A/B] |
+ | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/b/b2/EM112_Solar.PNG EM112-DIN AV1 1 X S1 PF B] | ||
| + | | + | ||
| rowspan="4" style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM112DS.pdf EM112] | | rowspan="4" style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM112DS.pdf EM112] | ||
|- | |- | ||
|230 V | |230 V | ||
− | | | + | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/f/f6/EM112.PNG EM112-DIN AV0 1 X S1 PF A/B] |
+ | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/b/b2/EM112_Solar.PNG EM112-DIN AV0 1 X S1 PF B] | ||
| + | | + | ||
|- | |- | ||
|120 V | |120 V | ||
− | | | + | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/8/81/EM112_Standard.PNG EM112-DIN AV1 1 X S1 X] |
+ | | | ||
| - | | - | ||
|- | |- | ||
|230 V | |230 V | ||
− | | | + | | style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/8/81/EM112_Standard.PNG EM112-DIN AV0 1 X S1 X] |
+ | | | ||
| - | | - | ||
|- | |- | ||
Line 79: | Line 85: | ||
| style="padding: 2px;" rowspan="2" | EM340 <br> | | style="padding: 2px;" rowspan="2" | EM340 <br> | ||
| style="padding: 1px;" | 400 V | | style="padding: 1px;" | 400 V | ||
− | | | + | | style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/a/a6/20230306130731%21EM340.PNG EM340-DIN AV2 3 X S1 PF A/B] |
+ | | style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/f/f8/EM340_Solar.PNG EM340-DIN AV2 3 X S1 PFB] | ||
| style="padding: 1px;" | + | | style="padding: 1px;" | + | ||
| style="padding: 2px;" rowspan="2" | [https://www.gavazzi.no/wp-content/uploads/EM340_DS_ENG.pdf EM340] | | style="padding: 2px;" rowspan="2" | [https://www.gavazzi.no/wp-content/uploads/EM340_DS_ENG.pdf EM340] | ||
Line 112: | Line 119: | ||
| style="padding: 2px;" | EM530 | | style="padding: 2px;" | EM530 | ||
| style="padding: 2px;" | 400 V | | style="padding: 2px;" | 400 V | ||
− | | style="padding: 2px;" | | + | | style="padding: 2px;" | |
− | | style="padding: 2px;" | | + | | style="padding: 2px;" | |
| style="padding: 1px;" | + | | style="padding: 1px;" | + | ||
| style="padding: 2px;" rowspan="2" | 3 phase | | style="padding: 2px;" rowspan="2" | 3 phase | ||
Line 120: | Line 127: | ||
| style="padding: 2px;" | EM540 | | style="padding: 2px;" | EM540 | ||
| style="padding: 2px;" | 400 V | | style="padding: 2px;" | 400 V | ||
− | | style="padding: 2px;" | | + | | style="padding: 2px;" | |
− | | style="padding: 2px;" | | + | | style="padding: 2px;" | |
| style="padding: 1px;" | + | | style="padding: 1px;" | + | ||
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM540_DS_ENG.pdf EM540] | | style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM540_DS_ENG.pdf EM540] |
Revision as of 13:14, 17 May 2023
Carlo Gavazzi smart energy meters technical information
*DLB - Dynamic load balancing
Carlo Gavazzi meters wiring:
Note 1: All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory.
Note 2: Ensure that the power is off before proceeding with the wiring
1st series to TeltoCharge connection
3rd and 5th series to TeltoCharge connection
Powering the energy meter
To correctly connect smart energy meter to power source, it is recommended to use manufacturers installation manuals.