General specifications

Teltocharge tethered with Type 1 cable

Picture of Tethered version charger
Dimensions without cable 170x341x97 mm
Weight without cable 2.8 kg
Operating temperature -30°C - +50°C
IP rating IP55
IK rating IK10
Certification UL2594
In compliance with IEC 61851-1

Electrical specifications

Here you can find information about electric parameters of Teltocharge product

AC INPUT SPECIFICATIONS
Maximum power 7,6 kW 9,6 kW 11,5 kW
Input AC power connection 2 phases
Maximum current 32 A 40 A 48 A
Input voltage 2 phases: (L-L) 240 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 20 mA AC, 6 mA DC
Overvoltage category OVC II
Protection against electric shock Class I
AC Output specifications
AC output voltage range 1 phase: (L-N) 240 ± 10% VAC
Connection Standart Type 1 cable
Connection to the grid NEMA 6-50 plug to the wall socket Direct cable from house grid

(Hardwired)

Power Cable
Maximum cable diameter 17.5 mm 20,75 mm
Maximum wire cross section 7.5 mm2

Product code structure

On the product Middle plate you can find markings showing its Product name and code, Certifications, Serial number and more.

Marking draft US .png
Model Version Power Connector Connectivity Front plate color Front plate finish
A B C D E F G
EVC 1 - V1 3 - US 7,6 kW, 1/2P, 32A, 120/240V

4 - US 9,6 kW, 1/2P, 40A, 120/240V

5 - US 11.5kW, 1/2P, 48A, 120/240V

1 - Tethered cable 0 - Without GSM modem P - Gray

R - Red

M - Blue

B - White

0 - N/A

0 –  Without front panel

1 – Tethered cable

Required tools

TeltoCharge Installation RequiredTools RequiredTools.PNG

List of required tools include:

A - Hammer
B - Electric drill
C - Pencil
D - Screwdriver
E - Cutting pliers
F - Allen key 2,5 mm
G - Measuring tape
H - Utility knife
I - Level
J - Drill bit D6

Included Mounting parts

TeltoCharge Installation IncludedMountingParts IncludedMountingParts.PNG

Included in the box you will find:

K - Wall plugs 6x35 mm
L - Pan head self-tapping screws galvanized steel
M - DIN912 M3x8 screws
N - Cable gland
O - Rubber washer

EV Charger Main elements

TeltoCharge Installation MainElements US.png

Site preparation requirements

  • Find a suitable site on a wall (The mounting surface required to be flat and stable, for example a finished, brick or concrete wall. Wall required to be suitable to withstand TeltoCharge weight with charging cable)​.
  • Make sure that the required power supply is easily accessible. (Required power supply depends on the type of charger).
  • Recommendation is not to install TeltoCharge on direct sunlight to avoid overheating.

Installation process

Housing Installation

TeltoCharge Installation InstallationProcess DrillingA.pngA - Place the drilling template on the wall and mark the three fixing points.

TeltoCharge Installation InstallationProcess DrillingB.pngB - Drill holes where the fixing points are marked.

TeltoCharge Installation InstallationProcess DrillingC.pngC - Insert the wall plugs into the fixing holes.

TeltoCharge Installation InstallationProcess HousingInstallation.png

Fix the device on the wall by inserting the self-tapping screws with rubber washers (start with the top screw and make sure the housing is horizontal)

Electrical wiring

TeltoCharge Installation ElectricalWiring US.png

Network type:
A - IT/TT two phase set up.

Notice 1: Products EVC131 (32Amp) and EVC141 (40 Amp) come with pre-wired NEMA 6-50 plug. These models have to be connected to pro properly selected wall socket which meets the same NEMA 6-50 standard.
Notice 2: Voltages in different installations may vary. Please check configuration of Installer menu Connection type settings in mobile application and select either delta or star connection.

Closing the middle panel

TeltoCharge Installation ClosingMiddlePanel US.png

A - Place a middle panel on the housing and press it, till it clicks.

B - Fix it using DIN912 M3x8 screws;

Closing the front plate;

TeltoCharge Installation ClosingFrontPanel US.png

C - Lock the top of the plate;

D - Lock the bottom of the plate;

E - Fix it using DIN912 M3x8 screws;

LED indicators

Information about how LED indicators signal different states can be obtained from here

Mobile application

Connection to the EV charger

Step 1 - Download the Teltonika Energy App

Teltocharge Installation AppDownload QR.png

Step 2 - Pair a charger and mobile device using Bluetooth. Device will ask to insert Pairing code which is represented by last 6 digits of Installer code. Sticker with security code can be found on the Middle plate.

Teltocharge Installation SecurityCode Sticker.png
  • More details on pairing procedure can be found in FAQ section of Wiki page.

Basic parameters


SET UP BASIC PARAMETERS
Step 1 - Type the EV charger name
Step 2 - Set currency
Step 3 - Set average price of kWh
Step 4 - In the next window enable authorization (if needed)
Step 5 - Set installer parameters
Step 6 - Confirm changes

Installer parameters


SET UP BASIC PARAMETERS
A - Installer menu can be reached via:

  • first time connection wizard window
  • APP settings

B - Every time an installer will be requested to type in a security code. Originally, the code can be found on the middle plate sticker. Please remember the place if you replace it.
C - If the security code is typed correctly, the installer can reach Installer parameters. Updated and detailed explanation can be found in the Teltonika Energy APP functions Wiki page

Safety and maintenance notes


Installation, maintenance, and servicing of the charger must be done only by the personnel with relevant qualifications under the applicable local regulations. Unauthorized installation and modifications make the manufacturer’s warranty void. Do not use the charger if the enclosure or connector is cracked, opened, broken, or shows any other indication of damage. If the connector begins to melt or emits smoke, do not touch it. If possible, stop charging activities. Before opening the cover or cleaning the charger, power down the device. Do not use cleaning solvents on any part of the charger. Use a clean, dry cloth to remove dust and dirt. Do not open the cover in the rain. Use the TeltoCharge charger under the operating parameters and within normal ambient conditions specified in the General and Electrical Specifications. Avoid installing the charger in a place that is under extreme weather conditions or is directly impacted by sunlight.

SIMPLIFIED DECLARATION OF CONFORMITY
Hereby, Teltonika Energy declares that TeltoCharge equipment is in compliance with UL2594 and UL 2331.

SAFETY RECOMMENDATIONS
Follow all the safety and installation instructions carefully. Failure to follow instructions may be a safety hazard and/or cause equipment malfunction. Any resulting damage due to disregard or actions contrary to the instructions in this manual is excluded from the product warranty.

CONNECTOR RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS
Do not use if the charging cable is frayed, has broken insulation, or has any signs of damage or the vehicle plug or electrical outlet is dirty, wet, or damaged. Do not use the charging cable with a cable adaptor or an extension cable. Under any circumstances, do not tighten the charging cable while it is connected.

INSTALLATION INSTRUCTIONS
Ensure that the mounting surface can adequately support the weight of the charger and withstand mechanical forces associated with usage. The charger must be permanently connected to the electrical Earth of the installation. Do not install the charger in direct sunlight, or near flammable, explosive, or combustible materials, chemicals or solvents, gas pipes or steam outlets, radiators or batteries, and areas prone to flooding, high humidity and running water.

ELECTRICAL PROTECTION
The power supply line must be wired to an existing installation and be in accordance with local regulations.

DISPOSAL ADVICE
In accordance with the Directive 2012/19/EC, at the end of its useful life, the product should not be disposed of as urban waste. It should be taken to a collection center or to a distributor that provides special and differentiated waste disposal.

LEGAL NOTICE
Any information in this manual may be changed without prior notice and does not represent any obligation on the part of the manufacturer. Images in this manual are for illustration purposes only and might differ from the delivered product.