Difference between revisions of "Eastron settings"

From Wiki
m (Protected "Eastron settings" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
Line 1: Line 1:
 
==== RS485 parameters for energy meters Eastron SMD54-M ; SMD72D-M V2  ====  
 
==== RS485 parameters for energy meters Eastron SMD54-M ; SMD72D-M V2  ====  
''Note: Energy meter parameters should match EVSE default parameters.''
+
''Note 1: Energy meter parameters should match EVSE default parameters.'' <br>
 +
''Note 2: Eastron energy meters booting time is longer than others.''
  
 
{| class="wikitable" style="text-align: center; border: 1px solid #0054A6; font-family: arial, sans-serif; width: 60%;"
 
{| class="wikitable" style="text-align: center; border: 1px solid #0054A6; font-family: arial, sans-serif; width: 60%;"

Revision as of 09:15, 10 March 2023

RS485 parameters for energy meters Eastron SMD54-M ; SMD72D-M V2

Note 1: Energy meter parameters should match EVSE default parameters.
Note 2: Eastron energy meters booting time is longer than others.

RS485 parameter EVSE default parameter value (configurable in mobile app)
Modbus adress 1
Baud rate 9600
Parity None
Stop bits 1