Difference between revisions of "LED indicators"
From Wiki
Line 69: | Line 69: | ||
!F | !F | ||
!G | !G | ||
− | ! | + | !H |
|- | |- | ||
|[[File:TeltoCharge LEDS InputVoltageError.png|center|frameless]] | |[[File:TeltoCharge LEDS InputVoltageError.png|center|frameless]] | ||
Line 87: | Line 87: | ||
|Internal errors. | |Internal errors. | ||
|Faulty connection to EV. | |Faulty connection to EV. | ||
− | | | + | |Warning orange LED |
|- | |- | ||
|Overvoltage; | |Overvoltage; | ||
Undervoltage; | Undervoltage; | ||
− | Wrong wiring | + | Wrong wiring. |
|Overvoltage; | |Overvoltage; | ||
Undervoltage; | Undervoltage; | ||
− | Output current | + | Output current. |
|Current leakage detected | |Current leakage detected | ||
|Cable lock; | |Cable lock; | ||
PP fail; | PP fail; | ||
− | Car diode | + | Car diode. |
|Temperature reached 85°C | |Temperature reached 85°C | ||
| -12V; | | -12V; | ||
|CP fail | |CP fail | ||
− | | | + | |Problems with energy meter: |
+ | |||
+ | * Unrecognized; | ||
+ | * Badly set; | ||
+ | * Communication problems; | ||
+ | * Temperature; | ||
+ | * Current ; | ||
+ | * D state. | ||
|- | |- | ||
− | | colspan=" | + | | colspan="8" |<center><big>Troubleshooting</big></center> |
− | |||
|- | |- | ||
| | | |
Revision as of 13:03, 19 December 2022
A | B | C | D | E | F | G | H | I | J | K | L | M |
---|---|---|---|---|---|---|---|---|---|---|---|---|
White LED‘s rolling from the bottom to the top – shows that TeltoCharge is booting up | White pulsing LED‘s – shows that TeltoCharge is in standby mode and waiting for action | Yellow pulsing LED‘s – shows that TeltoCharge is in standby mode with default settings. | Yellow LED‘s on – TeltoCharge is not charging, simplified charging sequence is required. | Blue LED‘s lights up from the middle – TeltoCharge do not require permission, it is waiting for EV to initiate charging process (go to state C). | Blue LED‘s pulsing – permission to charge is not granted. TeltoCharge requires authorization. | Four middle blue LED’s pulsing – TeltoCharge waiting to add new NFC card | Green LED‘s pulsing - Initialisation of charging. | Green LED‘s rolling upwards from the bottom – TeltoCharge is in charging process. | Green LED‘s on – TeltoCharge finished charging. | Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D). | Red four middle LED's - NFC/RFID card declined from the server. | Green four middle LED's - NFC/RFID card accepted from the server. |
Open installer menu via Teltonika Energy app, set and save settings. | Open installer menu via Teltonika Energy app and select to allow simplified charging sequence | Authorize yourself with app or NFC card. | Open installer menu via Teltonika Energy app and select that charging location is ventilated. To select that charger must be installed in ventilated location. | Check if NFC/RFID card is in a server cards whitelist. |
RED LED indicators (errors)
A | B | C | D | E | F | G | H |
---|---|---|---|---|---|---|---|
Input voltage error. | Output voltage/current error. | Current leakage detected. | Connectivity error. | Temperature error. | Internal errors. | Faulty connection to EV. | Warning orange LED |
Overvoltage;
Undervoltage; Wrong wiring. |
Overvoltage;
Undervoltage; Output current. |
Current leakage detected | Cable lock;
PP fail; Car diode. |
Temperature reached 85°C | -12V; | CP fail | Problems with energy meter:
|
|
|
|
|
|
|
|
|