*'''ECO+ charging profile''' - In this profile, the charging process is initiated using a combination of solar energy and grid energy. The user sets the ECO+ surplus minimum value, which determines the minimum surplus energy required to start the charging process. If the set value is less than 6A, the difference in current will be supplemented with grid power.
 
*'''ECO+ charging profile''' - In this profile, the charging process is initiated using a combination of solar energy and grid energy. The user sets the ECO+ surplus minimum value, which determines the minimum surplus energy required to start the charging process. If the set value is less than 6A, the difference in current will be supplemented with grid power.
   −
Example:
+
Example:<br>
     ''ECO+ surplus minimum value set to 1 A
+
     ECO+ surplus minimum value set to 1 A<br>
     0 A (from solar) = charging process is not initiated
+
     0 A (from solar) = charging process is not initiated<br>
     1 A (from solar) + 5 A from grid = 6 A charging current
+
     1 A (from solar) + 5 A from grid = 6 A charging current<br>
     5 A (from solar) + 1 A from grid = 6 A charging current
+
     5 A (from solar) + 1 A from grid = 6 A charging current<br>
 
     10 A (from solar) + 0 A from grid = 10 A charging current''
 
     10 A (from solar) + 0 A from grid = 10 A charging current''
 
*'''ECO charging profile''' - In this profile, the charging process is initiated using maximum available solar energy in combination with grid energy. The user sets the ECO charging minimum value, which determines the minimum charging current. This charging current is first covered by the maximum solar energy available and then supplemented with grid energy.
 
*'''ECO charging profile''' - In this profile, the charging process is initiated using maximum available solar energy in combination with grid energy. The user sets the ECO charging minimum value, which determines the minimum charging current. This charging current is first covered by the maximum solar energy available and then supplemented with grid energy.
   −
Example:
+
Example:<br>
 
+
     ECO charging minimum value set to 10 A<br>
     ''ECO charging minimum value set to 10 A
+
     If 5 A (from solar) + 5 A from grid = 10 A charging current<br>
     If 5 A (from solar) + 5 A from grid = 10 A charging current
+
     If 9 A (from solar) + 1 A from grid = 10 A charging current<br>
     If 9 A (from solar) + 1 A from grid = 10 A charging current
+
     If 16 A (from solar) + 0 A from grid = 16 A charging current<br>
     If 16 A (from solar) + 0 A from grid = 16 A charging current
   
     If 0 A (from solar) + 10 A from grid = 10 A charging current''
 
     If 0 A (from solar) + 10 A from grid = 10 A charging current''
    