Line 44: |
Line 44: |
| #'''ECO+ surplus minimum''' - This setting requires the minimum value of surplus solar energy to be reached in order to initiate a charging session. If the minimum value of surplus energy is not achieved, the charger will remain in "On hold" mode, awaiting additional surplus energy. <br> | | #'''ECO+ surplus minimum''' - This setting requires the minimum value of surplus solar energy to be reached in order to initiate a charging session. If the minimum value of surplus energy is not achieved, the charger will remain in "On hold" mode, awaiting additional surplus energy. <br> |
| #'''ECO charging minimum''' - This setting specifies the minimum value required to commence the charging process. | | #'''ECO charging minimum''' - This setting specifies the minimum value required to commence the charging process. |
| + | <br> |
| + | <br> |
| + | |
| + | |
| + | <h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;"> Charging modes </h2> |
| + | <ol style="list-style-type: none; margin: 0; padding: 0;"> |
| + | |
| + | With TeltoCharger chargers, you can achieve three different solar charging modes, each offering unique benefits for various situations:<br> |
| + | |
| + | #'''Solar only charging profile''' - In this profile, the charging process is initiated solely using green energy. The minimum required value is 6 Amps. If there is less surplus energy available than 6 A, the charger will remain in "On hold" mode. |
| + | #'''ECO+ charging profile''' - In this profile, the charging process is initiated using a combination of solar energy and grid energy. The user sets the ECO+ surplus minimum value, which determines the minimum surplus energy required to start the charging process. If the set value is less than 6A, the difference in current will be supplemented with grid power. |
| + | |
| + | Example: |
| + | ECO+ surplus minimum value set to 1 A |
| + | 0 A (from solar) = charging process is not initiated |
| + | 1 A (from solar) + 5 A from grid = 6 A charging current |
| + | 5 A (from solar) + 1 A from grid = 6 A charging current |
| + | 10 A (from solar) + 0 A from grid = 10 A charging current |
| + | #'''ECO charging profile''' - In this profile, the charging process is initiated using maximum available solar energy in combination with grid energy. The user sets the ECO charging minimum value, which determines the minimum charging current. This charging current is first covered by the maximum solar energy available and then supplemented with grid energy. |
| + | |
| + | Example: |
| + | |
| + | ECO charging minimum value set to 10 A |
| + | If 5 A (from solar) + 5 A from grid = 10 A charging current |
| + | If 9 A (from solar) + 1 A from grid = 10 A charging current |
| + | If 16 A (from solar) + 0 A from grid = 16 A charging current |
| + | If 0 A (from solar) + 10 A from grid = 10 A charging current |
| | | |
| <ul style="list-style-type: none; margin: 0; padding: 0;"> | | <ul style="list-style-type: none; margin: 0; padding: 0;"> |