5,396 bytes added
, 20:39, 30 March 2023
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">Introduction</h2>
<ul style="list-style-type: none; margin: 0; padding: 0;">
Here you can find information about '''Suggested configuration of 11 kW power TeltoCharge installer menu''' parameters according to your '''electrical grid'''.
<br>
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">3 phase (3L+N+PE) | voltage between L-N 230V ± 10% | L-L 400V ± 10%</h2>
<ul style="list-style-type: none; margin: 0; padding: 0;">
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">Suggested installer menu configuration guide</h2>
<ul style="list-style-type: none; margin: 0; padding: 0;">
Follow these steps to get started with TeltoCharge in a '''maximum''' 11 kW power:
<br>
{| class="wikitable" style="text-align: center; border: 1px solid #0054A6; font-family: arial, sans-serif; width: 60%;"
|-
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Option number in installer
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Installer menu parameter name
! style="background-color: #0054A6; color:#FFFFFF; padding: 4px;" | Suggested value to set
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Link to description of parameter
|-
| style="padding: 8px;" | 01
| style="padding: 8px;" | '''Max power from grid'''
| style="padding: 8px;" | 16 A
| style="padding: 8px;" | [[Max power from grid]]
|-
| style="padding: 8px;" | 02
| style="padding: 8px;" | '''Supply voltage '''
| style="padding: 20px;" | 230 V
| style="padding: 8px;" | [[Supply voltage]]
|-
| style="padding: 8px;" | 03
| style="padding: 8px;" | '''Upper voltage tolerance'''
| style="padding: 8px;" | 10 %
| style="padding: 8px;" | [[Upper voltage tolerance]]
|-
| style="padding: 8px;" | 04
| style="padding: 8px;" | '''Lower voltage tolerance'''
| style="padding: 8px;" | 10 %
| style="padding: 8px;" | [[Lower voltage tolerance]]
|-
| style="padding: 8px;" | 05
| style="padding: 8px;" | '''Phase priority'''
| style="padding: 8px;" | L1
| style="padding: 8px;" | [[Phase priority]]
|-
| style="padding: 8px;" | 06
| style="padding: 8px;" | '''Difference between phases'''
| style="padding: 8px;" | 180 °
| style="padding: 8px;" | [[Difference between phases]]
|-
| style="padding: 8px;" | 07
| style="padding: 8px;" | '''Use neutral as phase'''
| style="padding: 8px;" | OFF
| style="padding: 8px;" | [[Use neutral as phase]]
|-
| style="padding: 8px;" | 08
| style="padding: 8px;" | '''Use data from energy meter'''
| style="padding: 8px;" | OFF
| style="padding: 8px;" | [[Use data from energy meter]]
|-
| style="padding: 8px;" | 09
| style="padding: 8px;" | '''kWh meter address'''
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - follow link on the right.''
| style="padding: 8px;" rowspan="5" | [https://wiki.teltonika-energy.com/view/Smart_energy_meters#TeltoCharge_supported_smart_energy_meters Choose your Smart energy meter and its parameters]
|-
| style="padding: 8px;" | 10
| style="padding: 8px;" | '''Energy meter type'''
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
|-
|-
| style="padding: 8px;" | 11
| style="padding: 8px;" | '''RS-485 baudrate'''
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
|-
| style="padding: 8px;" | 12
| style="padding: 8px;" | '''RS-485 parity'''
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
|-
| style="padding: 8px;" | 13
| style="padding: 8px;" | '''RS-485 stop bit'''
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
|-
| style="padding: 8px;" | 14
| style="padding: 8px;" | '''Dynamic load balancing'''
| style="padding: 8px;" | OFF
| style="padding: 8px;" | [[Dynamic Load Balancing]]
|-
| style="padding: 8px;" | 15
| style="padding: 8px;" | '''Use preferred phase'''
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.'''
| style="padding: 8px;" | [[Use prefered phase]]
|-
| style="padding: 8px;" | 16
| style="padding: 8px;" | '''Energy meter address'''
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
| style="padding: 8px;" | [https://wiki.teltonika-energy.com/view/Smart_energy_meters#TeltoCharge_supported_smart_energy_meters Choose your Smart energy meter and its parameters]
|-
| style="padding: 8px;" | 17
| style="padding: 8px;" | '''Allow simplified charging sequence'''
| style="padding: 8px;" | OFF
| style="padding: 8px;" | [[Allow simplified charging sequence]]
|-
| style="padding: 8px;" | 18
| style="padding: 8px;" | '''Charger location is ventilated'''
| style="padding: 8px;" | OFF (if your TeltoCharge is inside the property)
| style="padding: 8px;" | [[Charger location is ventilated]]
|-
| style="padding: 8px;" | 19
| style="padding: 8px;" | '''Temperature warning'''
| style="padding: 8px;" | 60 °C
| style="padding: 8px;" | [[Temperature warning]]
|}