Line 1: Line 1:  +
=Cable lock=
 +
There is a possibility to activate cable lock on demand even if the charging is not initiated.
 +
 +
* When Cable lock is ON, the locking pin pushes out and fixes charging cable in place.
 +
* When Cable lock is set to AUTO, locking pin behaves accordingly to the charging state the product is in.
 +
** A state - Cable is not locked;
 +
** B/C/D states - Cable is locked;
 +
 +
 +
''By default this status is set to AUTO''
 +
 +
 
=Authorization=
 
=Authorization=
 
There is possibility to turn ON/OFF authorization for TeltoCharge.  
 
There is possibility to turn ON/OFF authorization for TeltoCharge.  
Line 4: Line 16:  
When authorization is ON, user have to authorize every time he wants to start charging process. Authorization can be done in two different ways:
 
When authorization is ON, user have to authorize every time he wants to start charging process. Authorization can be done in two different ways:
   −
* By swiping the Slider in main menu;
+
*By swiping the Slider in main menu;
* By using NFC card;
+
*By using NFC card;
      Line 25: Line 37:  
''By default, NFC cards whitelist is empty.''
 
''By default, NFC cards whitelist is empty.''
   −
=Connectivity=
+
= Connectivity=
 
In the connectivity tab user can connect TeltoCharge to internet via Wi-Fi, Ethernet cable or GSM card (if it is selected as product option).  
 
In the connectivity tab user can connect TeltoCharge to internet via Wi-Fi, Ethernet cable or GSM card (if it is selected as product option).  
   Line 33: Line 45:  
To connect Teltocharge to Wi-Fi, just follow these steps:
 
To connect Teltocharge to Wi-Fi, just follow these steps:
   −
* Open Wi-Fi tab;
+
*Open Wi-Fi tab;
* Enable it with the slider;
+
*Enable it with the slider;
* Select your network from provided list;
+
*Select your network from provided list;
* Insert password and press save;
+
*Insert password and press save;
* Wait until product is connected successfully;        
+
*Wait until product is connected successfully;
   −
==Mobile==
+
==Mobile ==
 
To connect TeltoCharge to cellular data first of all nano SIM card have to be inserted to the SIM card port. After that just enable Mobile Internet in the Connectivity tab with the slider.
 
To connect TeltoCharge to cellular data first of all nano SIM card have to be inserted to the SIM card port. After that just enable Mobile Internet in the Connectivity tab with the slider.
    
Mobile internet tab also has got some configurations which can be set by user:
 
Mobile internet tab also has got some configurations which can be set by user:
   −
* ''PIN code''
+
*''PIN code''
* ''APN adress''
+
*''APN adress''
* ''Username''
+
*''Username''
* ''Password''
+
*''Password''
* ''Dialing number''
+
*''Dialing number''
    
==OCPP==
 
==OCPP==
Line 59: Line 71:  
More information anout OCPP you can find [[OCPP FAQ|here]].
 
More information anout OCPP you can find [[OCPP FAQ|here]].
   −
==Ethernet==
+
==Ethernet ==
 
To connect TeltoCharge with Ethernet just plug in the cable and all needed settings should be set automatically.   
 
To connect TeltoCharge with Ethernet just plug in the cable and all needed settings should be set automatically.   
   Line 86: Line 98:  
This configuration shall be used in two different ways:
 
This configuration shall be used in two different ways:
   −
* If you <u>are</u> using Dynamic load balancing, use this value to set the maximum current per phase that can be supplied to the whole electrical installation. Usually this value is the rated current of the main circuit breaker.
+
*If you <u>are</u> using Dynamic load balancing, use this value to set the maximum current per phase that can be supplied to the whole electrical installation. Usually this value is the rated current of the main circuit breaker.
 
* If you <u>are no</u>t using Dynamic load balancing, use this value to set maximum current, which charger can use. This value should be calculated according to the possible load, that other appliances can be using, by subtracting it from the maximal current which is provided to the grid. That said, in this situation, current should not be higher than 16 amperes (If 11 kW charger is installed) or 32 amperes ( if 7,4 or 22 kW chargers is installed).
 
* If you <u>are no</u>t using Dynamic load balancing, use this value to set maximum current, which charger can use. This value should be calculated according to the possible load, that other appliances can be using, by subtracting it from the maximal current which is provided to the grid. That said, in this situation, current should not be higher than 16 amperes (If 11 kW charger is installed) or 32 amperes ( if 7,4 or 22 kW chargers is installed).
   Line 94: Line 106:  
==Supply voltage==
 
==Supply voltage==
   −
* Installer can change supply voltage (''voltage between phase and neutral wires'')
+
*Installer can change supply voltage (''voltage between phase and neutral wires'')
* Different regions can have different supply voltages, so installer can set this value accordingly to the used voltage in the individual site;
+
*Different regions can have different supply voltages, so installer can set this value accordingly to the used voltage in the individual site;
      Line 106: Line 118:  
''By default this setting is set to 10 %''
 
''By default this setting is set to 10 %''
   −
==Lower voltage tolerance==
+
== Lower voltage tolerance==
 
There is possibility to change the tolerance limit for lower voltage threshold. This can be used in the sites where voltage fluctuation is big.
 
There is possibility to change the tolerance limit for lower voltage threshold. This can be used in the sites where voltage fluctuation is big.
   Line 162: Line 174:  
''By default this setting is set to 60 °C''
 
''By default this setting is set to 60 °C''
   −
== Factory default settings ==
+
==Factory default settings==
 
By using this setting installer can restore Factory default settings. This function restores all settings which were set in the Installer menu as well as in the Main menu.
 