Changes

418 bytes added ,  04:59, 24 October 2022
no edit summary
Line 9: Line 9:     
''By default this status is set to AUTO''
 
''By default this status is set to AUTO''
 +
''Settings can only be found in socket variant products''
    
=Authorization=
 
=Authorization=
Line 51: Line 52:     
==Mobile ==
 
==Mobile ==
 +
''Optional"
 
To connect TeltoCharge to cellular data first of all nano SIM card have to be inserted to the SIM card port. After that just enable Mobile Internet in the Connectivity tab with the slider.
 
To connect TeltoCharge to cellular data first of all nano SIM card have to be inserted to the SIM card port. After that just enable Mobile Internet in the Connectivity tab with the slider.
   Line 101: Line 103:       −
''By default this setting is set to 10 Amps''
+
'' By default this setting is set to 10 Amps''
 +
 
    
==Supply voltage==
 
==Supply voltage==
Line 110: Line 113:     
''By default this setting is set to 230 V''
 
''By default this setting is set to 230 V''
 +
''By default this setting is set to 120 V''
    
==Upper voltage tolerance==
 
==Upper voltage tolerance==
Line 128: Line 132:     
''By default this setting is turned OFF''
 
''By default this setting is turned OFF''
 +
''Not available in North America products''
    
==Phase priority==
 
==Phase priority==
Line 137: Line 142:     
''By default this setting is set to L1''
 
''By default this setting is set to L1''
 +
''Not available in North America products''
    
==Dynamic load balancing==
 
==Dynamic load balancing==
Line 143: Line 149:     
''By Default this setting is turned off''
 
''By Default this setting is turned off''
 +
''Not available in North America products''
    
==Use preferred phase==
 
==Use preferred phase==
Line 149: Line 156:     
''By default this setting is turned off''
 
''By default this setting is turned off''
 +
    
==Connection type==
 
==Connection type==
 
This function let user to select how theirs power input is wired - in Star network or Delta network style.
 
This function let user to select how theirs power input is wired - in Star network or Delta network style.
   −
''By default this setting is marked as Star''
+
''Global product: By default this setting is marked as Star''
 +
''North American product: By default this setting is marked as Delta''
    
==Use neutral as phase==
 
==Use neutral as phase==
 
This function allows user to use electrical network without Neutral wire. L1 then must be connected to N(L1) pin in input terminal.
 
This function allows user to use electrical network without Neutral wire. L1 then must be connected to N(L1) pin in input terminal.
   −
''By default this setting is turned off''
+
''Global product: By default this setting is turned OFF''
 +
 
 +
''North American product: By default this setting is turned ON''
    
==Allow simplified charging sequence==
 
==Allow simplified charging sequence==